Search:


Comp II LED Comp II SCX Black SCX Silver SCX White 60s Muscle MINI Factory Match Liquid Filled Non-Filled Direct Mount Engine Thermometers Accessories All Gauges
1" Dial (K) 1½" Dial (A) 2¼" Dial (B) 3" Dial (E) 3" Asphalt (E) 3" Bottom Mount (J) 3" Asphalt (J) 3" Adjustable (ADJ3) 5" Dial (G) 5" Adjustable (ADJ5) 5" Bottom Mount (GJ) Engine Thermometers Capillary Industrial All Thermometers
Utility, Lower Mount SS/Brass, Lower Mount SS/Brass, Center Back SS/Brass, U-Clamp SS/Brass, Panel Mount All SS, Lower Mount All SS, Panel Mount 4" All SS 4.5" Process Gauges
2" All SS (Q3) 2½" All SS (K) 2½" SS/Brass (J) 4" All SS (G) 4½" Process (MPB/SC) 6" All SS (H) All McDaniel Gauges
General Service Severe Service 63mm Severe Service 100mm Diaphragm Gauges Process Gauges All MARSH Gauges MARSH PDF Catalog
Address, Phone, Fax Request Info
Contact Us About Marshall Search Catalog FAQs Site Index

How can I troubleshoot my electric temperature gauge?

Verify Wiring and Common Ground
Verify your wiring is good and that the gauge and sender both have a good common ground (ground both to the same place on the chassis).

Verify Ohm Signal from Sending Unit
Turn your vehicle on and let it warm up. Disconnect the gauge signal wire from the sender and check the ohms output between the sender and common ground/chassis with a multimeter. Compare the ohms output with the expected ohm output at warm temperature. Temp/Ohm data for the SCX and Comp II temperature senders can be found on the respective product pages:

If the sender is not reading as expected contact us for a replacement.

Verify Ohm Signal at the Gauge
Reconnect the gauge signal wire to your sender, disconnect the signal wire from the gauge and check the ohms between the signal wire and gauge ground wire (signal wire needs to be disconnected from the gauge). The ohm reading should be the same as you measured at the sender. If it is not, then you will need to check your wiring (use smaller gauge wire, verify common ground etc.).

Verify the Gauge
Check the SCX or Comp II temp/ohm data on the respective pages above and confirm that the gauge is reading at the expected temperature for the ohms reading at the gauge. Example: at 200 ohms, the SCX temp gauge should read approx 180F. If the gauge is not reading as expected contact us to return your gauge for checking/replacement.